AB Analitica RealQuality Real-Time PCR Identification Kits

RealQuality RI-HPV STAR (RI-01)

The RealQuality RI-HPV STAR kit is for the identification of HPV by Real-Time PCR, with the option to genotype directly on a strip.

Starting Material: DNA extracted from cervical/vaginal swabs.
Amplified Region: L1 protein gene.
Reaction Mix: Ready-to-use reagents including a fluorescent normaliser, dUTP/UNG system for prevention of contamination.
Internal Control: β-globin (BG) gene amplification.
Positive Controls: DNA containing part of the HPV genome and BG gene.
Run Time: 150 minutes.

The HPV positive sample can be directly genotyped by reverse hybridisation on strips using AmpliQuality kits HPV-TYPE (03-29R) and AmpliQuality HPV-TYPE HR (03-30R).

RealQuality RQ-HPV HR (RQ-22)

The RealQuality RQ-HPV HR kit is for the identification and genotyping of 8 high risk HPV types – 16, 18, 31, 33, 45, 52, 58 and 67 – and has been validated on the ABI 7000/7300/7500 (Applied Biosystems) and I-Cycler (Bio-Rad).

Back to Top
 

AB Analitica AmpliQuality End-Point PCR Identification Kits


AmpliQuality HPV-HS-Bio (03-23A and 03-23R)

The AmpliQuality HPV-HS-Bio kit is for the identification of HPV by nested PCR, with the option to genotype directly on a strip.

Kits Include:

The biotinylated nested PCR product can be used for HPV genotyping by reverse hybridisation on strips using AmpliQuality kits HPV-TYPE (03-29R) and AmpliQuality HPV-TYPE HR (03-30R).

Back to Top

 

AB Analitica AmpliQuality Typing on Strips Kits

These kits, which contain only strips and typing reagents, can be used with the biotinylated product obtained with RealQuality kit RI-HPV STAR (R1-01) and AmpliQuality kit HPV-HS-Bio (03-23A and 03-23R).

AmpliQuality HPV-TYPE (03-29R)

AmpliQuality HPV-TYPE is for genotyping by Reverse Line Blot of low and high-risk HPV types – 6, 11, 40, 42, 43, 44, 54, 61, 70, 72, 81, 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73 and 82. Other HPV types, not listed, will give a positive result to a universal HPV sequence on the strip.

AmpliQuality HPV-TYPE HR (03-30R)

AmpliQuality HPV-TYPE HR is for genotyping by Reverse Line Blot of high-risk HPV types – 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73 and 82.

Back to Top

 

AB Analitica AmpliQuality Identification and Typing on Strips Kits

AmpliQuality HPV-TYPE EXPRESS (03-35A)

The AmpliQuality HPV-TYPE EXPRESS kit is for the identification and typing of HPV by single-step PCR and Reverse Line Blot and is useful for higher volume screening of cytological samples (e.g. ThinPrep, SurePath) where high sensitivity is not required.  The kit can detect types 6, 11, 40, 42, 43, 44, 54, 61, 70, 72, 81, 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73 and 82. Other HPV types, not listed, will give a positive result to a universal HPV sequence on the strip. The amplification includes the dUTP/UNG system for the prevention of contamination due to carry over. On the strip, there is also a specific probe for TST gene detection, used as an amplification control of the extracted DNA.
 

Kit Includes:


AmpliQuality HPV-TYPE HS (03-29A)

The AmpliQuality HPV-TYPE HS kit is for the identification and typing of HPV by nested PCR and Reverse Line Blot and excellent for use with histological samples (formalin fixed and paraffin embedded) because of its high sensitivity.  The kit can detect types 6, 11, 40, 42, 43, 44, 54, 61, 70, 72, 81, 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73 and 82. Other HPV types, not listed, will give a positive result to a universal HPV sequence on the strip. On the strip, there is also a specific probe for TST gene detection, used as an amplification control of the extracted DNA.
 

Kit Includes:


Back to Top
 

AB Analitica Cytological Samples Collection Kit

The Cytological Samples Collection Kit contains a sterile device for sample collection (cytobrush type) and a vial containing 10mL of sterile buffer. The kit is particularly suitable for the collection and transport of gynaecological samples for diagnostic testing, including for HPV.

Back to Top

Back to Product Index

PCR Tests For HPV Identification and Typing Product List

Code Description Size
Kits For Human Papillomavirus
RI-01-48 RealQuality RI-HPV STAR 48 Tests
RI-01-96 RealQuality RI-HPV STAR 96 Tests
RQ-22-48 RealQuality RQ-HPV HR 48 Tests
RQ-22-96 RealQuality RQ-HPV HR 96 Tests
03-23A-25 AmpliQuality HPV-HS-Bio 25 Tests
03-23A-50 AmpliQuality HPV-HS-Bio 50 Tests
03-23R-25 AmpliQuality HPV-HS-Bio (Amplification Reagents Only) 25 Tests
03-23R-50 AmpliQuality HPV-HS-Bio (Amplification Reagents Only) 50 Tests
03-029R AmpliQuality HPV-Type (Strips & Typing Reagents Only) 20 Tests
03-30R AmpliQuality HPV-Type HR (Strips & Typing Reagents Only) 20 Tests
03-35A AmpliQuality HPV-Type Express 20 Tests
03-029A AmpliQuality HPV-Type HS 20 Tests
03-33R HPV-SCK Cytological Samples Collection Kit 100 Tests